Sign In | Join Free | My hardware-wholesale.com
China Shenzhen Wisdomlong Technology CO.,LTD logo
Shenzhen Wisdomlong Technology CO.,LTD
Shenzhen Wisdomlong Technology CO.,LTD Work hard and best service for you!
Verified Supplier

8 Years

Home > Digital I O Module >

RIO SLC 500 PLC Remote I O module Allen Bradley 1771-ASB

Shenzhen Wisdomlong Technology CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

RIO SLC 500 PLC Remote I O module Allen Bradley 1771-ASB

Brand Name : AB

Model Number : 1771-ASB

Place of Origin : USA

MOQ : 1

Price : negotiable

Payment Terms : T/T

Supply Ability : 100

Delivery Time : 5-8 work days

Packaging Details : New in original box

Certification : CE

Brand : AB

Model : 1771-ASB

Module Type : I/O Adapter Module

Product Family : SLC 500

Port : Universal Remote I/O Adapter

Product Type : RIO Adapter Module

Rate of Communication : 57.6 kbit/second, 115 kbit/second, 230 kbit/second

Communication Port : Remote I/O (RIO)

Contact Now

AB 1771-ASB , PLC 5 Remote I/O (RIO) Adapter Hardware

Technical Specifications for 1771-ASB

Manufacturer Rockwell Automation
Brand AB
Part Number/Catalog No. 1771-ASB
Module Type I/O Adapter Module
Product Family: SLC 500
Port Universal Remote I/O Adapter
Product Type: RIO Adapter Module
Rate of Communication 57.6 kbit/second, 115 kbit/second, 230 kbit/second
Connectors Wiring Arm 1771-WB
Programming software: RSLogix5 software
Backplane Current (at 5 Volts) 1.0 Amps
Communication Port: Remote I/O (RIO)
Operating Temperature 32°F to 140°F (0°C to 60°C)

Cable Belden 9463
Mounting: In-Chassis
Storage Temperature -40°F to +185°F (-40°C to +85°C)
Backplane Current: 1 mA at 5V dc
Lower Connector Keying 16 to 18
Noise Immunity: NEMA standard ICS 2-230
Humidity: 5% to 95% non-condensing
UPC 10612598127532
Number of connections: 32
Weight 1.9 pounds (0.9 kilograms)
Certifications: UL Listed, CSA certified, Class I, Division 2 Groups A, B, C, D, CE compliant for all applicable directives, Marine Certified, C-tick marked for all applicable acts
Dimensions 3.5 x 6.5 x 2.0 inches (89 x 165 x 51 millimeters)

About 1771-ASB

The AB 1771-ASB is a PLC 5 Universal Remote I/O Adapter Module. It interfaces with I/O modules in a 1771 I/O chassis with a Remote I/O scanner port for a processor over an I/O link. Using it instead of direct wiring reduces startup, installation, and maintenance costs by the I/O being closer to the actuators and sensors. It is compatible with 32 I/O-adapter devices via the I/O link and it uses 82 Ohm or 150 Ohm terminating resistor.

The 1771-ASB module has a communication rate of 57.6 Kbps, 115 Kbps, and 230 Kbps and it weighs 1.9 pounds. It has a backplane current load of 1 A at 5 Volts DC and a maximum power dissipation of 5.2W. It requires a remote I/O adapter port for connection. For installation, it must be mounted in the left-most slot of the 1771 chassis with the I/O modules controlled by a PLC 5 processor. For wiring, the 1770-CD Belden 9463 or equivalent cable must be used. The 1771-ASB module has Active, Adapter Fault, and I/O Rack fault diagnostic Indicators, 2 switch assemblies, and a field wiring arm. It provides faster data transmission and backplane scanning up to 2500 feet at 230.4K Baud. It supports serial communication and reads/writes data in parallel form. It supports 4, 8, 12, 16, or 32-slot I/O chassis and 1 and 2-slot I/O addressing. The 1771-ASB improves scan time and I/O image space savings by scanning all slots except the last 4. It eases troubleshooting with its enhanced diagnostics features.

The 1771-ASB is an AB hardware that belongs to the PLC 5 product family of Programmable Logic Controllers (PLC). This electronic hardware is a remote I/O adapter that is used to interface the to Remote I/O (RIO) network. In actual, this RIO adapter responds to the request of the Remote I/O (RIO) scanner in the network. This adapter supports transmission of data at cable length and speeds of 10,000 feet at 57.6K baud, faster backplane scanning and data transmission up 2500 feet at 230.4K baud.

RIO Communication is physically implemented following daisy-chain topology. In this topology, the start and end points must be installed with a terminating resistor to close the network segment. The same is true for this protocol, either an 82 Ohm or 150 Ohm resistor may be used to terminate the segment. 150 Ohm is used for older configuration while 82 Ohms is used in enhanced RIO network versions. Belden 9463 or more popularly known as Belden Blue Hose cable is used for Remote I/O protocol.

This module is provided with status indicators such as ACTIVE, ADAPTER FAULT, and I/O RACK FAULT. For the Active status, the LED light should be Green to indicate normal operation. When an adapter fault is experienced, Red light illuminates while for Rack Fault, RED led activates.

This module receives/sends data from/to the I/O scanner in serial form, reads/writes data from/to the input modules in parallel form, reads/writes data from/to the output modules in parallel form. Configuration software used with this module are RSLinx and RSLogix 5 programming software.


RIO SLC 500 PLC Remote I O module Allen Bradley 1771-ASB

RIO SLC 500 PLC Remote I O module Allen Bradley 1771-ASB


Product Tags:

PLC Remote I O Module

      

SLC 500 Remote I O Module

      

Allen Bradley 1771-ASB Logic Output Module

      
China RIO SLC 500 PLC Remote I O module Allen Bradley 1771-ASB wholesale

RIO SLC 500 PLC Remote I O module Allen Bradley 1771-ASB Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Wisdomlong Technology CO.,LTD
*Subject:
*Message:
Characters Remaining: (0/3000)